The Carnegie Mellon Partial Wave Analysis Project
- [24.October.1999]
IU PWA Page
- [01.June.2000]Summary of 3
Monte Carlo by Adam Szczepniak.
- [PostScript][pdf]
- [08.June.2000]Derivations
of angular distributions for the a2(1320).
- [html]
[PostScript]
[pdf]
- [09.June.2000]Some Distributions
- Mass and angular distributions as computed using Adam's weights.
- [13.June.2000]Status Report
- A brief description of where things stand on 13 June, 2000.
- [28.June.2000]Distributions from Dennis
- Distributions as generated by Dennis. The alpha distribution deviates from
those on June 9 because only
one refelctivity is allowed.
- [29.June.2000]Distributions for fit of unpolarized events
- This is the one-bin sample that will be used in fitting.
- [30.June.2000]Distributions of unpolarized events,
weighted by PWA2000.
- [30.Jume.2000]Status Report
- A brief description of where things stand on 30 June, 2000.
- [30.June.2000]Comment on defintion of the naturality basis for photons.
- by Adam Szczepaniak.
- [04.July.2000]Status Report
- More information on the weight-weight plots.
- [05.July.2000]Status Report
- Weight-weight issue has been resolved.
- [07.July.2000]Status Report
- Fits to Unpolarized Data.
- [10.July.2000]Status Report
- Update on the a1 fit.
- [12.July.2000]Status Report
- Update on the polarized a2 fit.
- [13.July.2000]Status Report
- Update on the polarized a2 fit, weights are now correct.
- [17.July.2000]
Note on parity relations
- [20.July.2000]Status Report
- General Staus Reports.
- [21.July.2000]Distributions
- Various Distributions from Adam's Blind File.
- [25.July.2000]Distributions
- Angular Distributions from Adam's Blind File.
- [26.July.2000]Intensity Distributions
- Computed Angular Distributions used in the Blind Fit.
- [27.July.2000]Fit Results
- Fit Results for the Polarized Blind Weight, (a2 bin)..
- [28.July.2000]Second Blind Fit
- We have completd a fit of the Blind Weighted events for a bin near the
2(1670).
- The weights can be viewed at here.
- [28.July.2000]
Adams Note on Naturality
- See Note Number 37
- [28.July.2000]A Draft of Curtis's PWA Talk.
- [PostSCript]
[pdf]
- [01.Aug.2000]Slides of Paul's PWA Study Talk.
- [HTML]
[ps]
- [03.Aug.2000]Update on PWA.
- We found an error in describing polarized events when alpha is not near 0 or 90.
- We now understand the polarized and unpolarized amplitudes.
- [05.Aug.2000]Adam's Results.
- Results of Adam's fitting procedure to the "blind function".
- [15.Aug.2000]Update on PWA.
- Fits have been performed in 20 MeV mass bins from 1000-2000 MeV.
- We are still waiting on the error code.
- [20.Aug.2000]Scott and Adams Test.
- IU Blind test performed by Scott on Adams fitting function.
- [22.Sep.2000]
Polarized Fits.
- Results for fits to the polarized photon beam. These include detector
resolution effects.
- [23.Sep.2000]
Unpolarized Fits.
- Results for fits to the unpolarized photon beam.
- [24.Sep.2000]
Error Comparisons.
- A comparison of errors from the 100% polarized and the unpolarized fits.
- [30.Oct.2000]More Fits.
- Fits to the blind weight using all waves that are in the weight, plus
additional weights which are not in the the weight.
|